ISO 5599
- Spool system: standard application
- Mixed system: suitable for a higher number of cycles, higher pressure and a better response time than a spool system for commutation.
→ Product unavailable? Request a quote.
Delivery throughout Europe
Secure payment
English speaker +33535565788
Characteristics:
- Operating temperature: -10 ÷ +50°C
- Fluid:
filtered air 50 µm (mixed system)
filtered air 50 µm, with or without dehumidification (spool system)
- Commutation system: spool system (standard application), mixed system (suitable for a higher number of cycles, higher pressure and a better response time than a spool system for commutation)
- Maximum pressure: 10 bar
- Connections: ISO 5599/1 interface
- Valve body: Acetalic resin coated with zamak
- Seals: NBR and polyurethane (mixed system), NBR (spool system)
- Electropilot/coil: AA/U3 series
- Power consumption: 2,5W (DC) - 5 VA (AC)
- Voltage DC 12V - DC 24V - AC 24V - AC 110V - AC 230V
- Manual override 2 positions - screw (BE), recessed button - 1 position (BE12)
BE-4000
2
5/2
2,3÷10
2
5/2
1÷10
2
5/2
1÷10
2
5/2
1÷10
Related products